QC Order And Test Templates
Quality Control settings define how QC orders are created, what users inspect, how samples are consumed, and how test results are recorded.
QC Order Type
| Field | System Impact |
|---|---|
| Name | QC order type selected during QC order creation and Auto QC generation. |
| Allow Manual No | Allows manual QC order numbering. |
| Allow Approve/Reject Qty | Allows users to record accepted and rejected quantities. |
| Stock Transfer Type | Required where QC movement creates or depends on stock transfer behavior. |
| Sample Consumption Required | Requires sample consumption during QC. |
| Serial No. Wise QC Order Required | Creates or requires QC tracking at serial-number level. |
| GI Type | Goods issue type used when sample consumption or related issue is posted. |
| Print Header / Footer / Layout | Controls QC order print output. |
If stock transfer is required, the stock transfer type must be selected. Sample consumption should be enabled only when inspection physically consumes material.
Test Parameters
Test Parameters define what is measured or checked.
| Field | System Impact |
|---|---|
| Name | Parameter shown in templates and QC order result entry. |
Examples include weight, dimension, purity, moisture, appearance, hardness, or packaging condition.
Test Methods
Test Methods standardize how a parameter is tested.
| Field | System Impact |
|---|---|
| Name | Method shown beside the parameter in QC templates and reports. |
Methods help inspectors apply the same test consistently.
Test Lists
Test Lists maintain reusable lists of accepted values.
| Field | System Impact |
|---|---|
| List Name | Name of the reusable list. |
| Sort Order Type | Controls how list items are ordered. |
| List Item Name | Allowed value that users can select during QC result entry. |
| Sort Order | Display order of the list item. |
At least one list item is required. Duplicate list items are blocked.
Test Templates
Test Templates combine headers, parameters, methods, specifications, and result types.
| Field | System Impact |
|---|---|
| Name | Template name selected on QC orders or Auto QC setup. |
| Remarks | Notes for inspectors or reviewers. |
| No Of Sample | Number of samples expected for inspection. |
| Active | Makes the template available for use. |
| Header | Section heading in the template. |
| Parameter | Test parameter to be inspected. |
| Method | Testing method to apply. |
| Type | Result type, such as list, range, or text. |
| Specification | Expected specification or acceptance criteria. |
| Range From / To | Numeric acceptance range where range type is used. |
| List | Accepted list values where list type is used. |
The template must contain at least one header or parameter. Name and sample count are mandatory.
Maintenance Guidance
Treat templates as controlled inspection plans. If a test requirement changes, review open QC orders before editing a template already in use. For major specification changes, create a new template so historical QC results remain understandable.