Recording Test Results
Use the Test action from the QC Orders list to record inspection results.
Test Template Grid
The test grid is built from the selected QC test template. It can include:
- test parameter
- test method
- one or more sample value columns
- overall value
- result
- specification
- remarks
The number of sample value columns is based on the No. of Samples entered for the QC Order.
Result Logic
For range-based tests, the system compares the entered value with the allowed specification range and marks the line as pass or fail. For list-based tests, the selected sample value controls the result. Text-based tests allow descriptive observations with a manually selected result.
Required Result Checks
Before saving a tested QC Order:
- every required test line must have a result
- final status must be selected
- department, plant, and store are required when sample consumption is posted
- serial-number items cannot post sample consumption
Final Status
The final status becomes Pass only when all required test results pass. If any required result fails, the QC Order is treated as failed.
Conclusion
Use the conclusion field to summarize the inspection decision, especially when the reading values need interpretation by stores, purchase, production, or dispatch teams.